Release time:2023-08-30
The bench is equipped with an intercooler control system according to needs, has a communication interface, and can adopt a hanging or trolley structure. The intercooler adopts domestic first-class brand. , hang and install above the bench or place the bench in the appropriate position. The inlet and outlet pipes of the intercooler are connected to the quick coupling valve on the upper quick coupling plate of the bench using high-strength metal bellows. The cooling water inlet is equipped with special filters, electronic control and manual control devices, and the inlet and outlet pipes are made of high-strength steel wire transparent bellows. The engine pressurized air intake system is connected with the upper quick release valve on the pallet using a manual quick coupling mechanism, which is convenient to operate and reliable to use. And adapt to changes in the variant. The pipe material is made of stainless steel SUS304.
Main technical parameters of intercooler control system: Temperature control adjustment range:
20-60°C; Automatic temperature control accuracy: ±2°C;
Inlet and outlet pressure difference: ≤750mmH2O; System pressure: ≥0.35MPa;
Cooling water pressure: 0.2-0.3MPa;
Pressure measurement accuracy± 0.2% F.S.
Cooling water can be recycled, with internal circulation pump to compensate for pressure loss in the system
With cooling water filter
The cooling water flow PID control valve (pneumatic proportional valve) set by the system changes the cooling water flow of the intercooler to achieve the cooling control after the engine intake air is boosted.
The temperature control accuracy of the intercooler outlet is ±2°C.